Merrychef E107: communication fault between the control boards
The touchscreen board and the power board have stopped talking to each other. The screen may show a communication error or stop responding.
Safety first. Sparks, or the crackle of electrical arcing: switch the oven off and do not use it again before a technician has examined it. Never take a cover off. Parts of the microwave circuit can stay charged at a dangerous voltage after the oven is unplugged.
What E107 means on your model
| Model | What the code means | What a technician inspects |
|---|---|---|
| eikon e2s and conneX 12/16 | Lost communication between touchscreen and power board. Either a communication error comes up on the screen, or the controls no longer react. | The cable that links the two boards and its connectors, then the boards themselves: the touchscreen controller (called QTS on the e2s, UI on the conneX) and the power board (SRB on the e2s, I/O on the conneX). |
| eikon e4s | Communication error between the touchscreen board (QTS) and the relay board (SRB). | On-site diagnosis with the e4s service procedure. |
On the e2s this entry can also be logged without a fault at the very first start-up and during a firmware update.
What staff can safely check
No safe check for staff. Note the full message and call.
Do not remove any cover, and do not try to bypass a door switch or a safety device. If the oven sparks, smells of burning or behaves abnormally, switch it off and leave it off.
What the code does not tell you
The code tells a technician where to start testing. It is not proof that one particular part has failed, and one code can have different causes depending on the model. That is why we test on site before recommending a repair.
Have these ready when you call
- Oven modelOn the rating plate at the back of the oven, for example eikon e2s or conneX 12.
- Serial numberAlso on the rating plate. On the e2s it shows briefly when the oven starts.
- Error codeThe code and the full message on the screen.
- A photoOf the screen or the oven, if you can take one.
- When it happensDuring preheat, mid-cycle, or as soon as it’s switched on.
Where this comes from. Entries were checked in November 2026 against the manufacturer’s own service manuals: eikon e2s (32Z3923), conneX 12 and 16 (32Z9170), eikon e4s (32Z3870), eikon e3 and e4, eikon e1s, conneX 12e, Mealstream EC401 and 402s. Meanings can still vary with the firmware and the manual revision.
E107 on your screen? Call us.
305-447-7384Monday–Friday, 9 AM–8 PM. For urgent weekend issues, leave a voicemail. Weekend messages are prioritized on Monday.