Merrychef E111: cavity temperature probe fault

The oven has lost its cavity temperature reading, or the reading is impossibly high.

Safety first. Sparks, or the crackle of electrical arcing: switch the oven off and do not use it again before a technician has examined it. Never take a cover off. Parts of the microwave circuit can stay charged at a dangerous voltage after the oven is unplugged.

What E111 means on your model

ModelWhat the code meansWhat a technician inspects
eikon e2s and conneX 12/16Fault on the cavity temperature probe. The cavity temperature reading disappears, or the oven shows a temperature far too high to be real.The thermocouple in the cavity, its connector and wiring, and the input on the control board that reads it.
eikon e4sCavity sensor failed: the thermocouple is open circuit or unplugged.On-site diagnosis with the e4s service procedure.

An open-circuit probe shows up as about 328°C in the oven’s log.

What staff can safely check

No safe check for staff. Note the full message and call.

Do not remove any cover, and do not try to bypass a door switch or a safety device. If the oven sparks, smells of burning or behaves abnormally, switch it off and leave it off.

What the code does not tell you

The code tells a technician where to start testing. It is not proof that one particular part has failed, and one code can have different causes depending on the model. That is why we test on site before recommending a repair.

See E111 in the full guide

Have these ready when you call

  • Oven modelOn the rating plate at the back of the oven, for example eikon e2s or conneX 12.
  • Serial numberAlso on the rating plate. On the e2s it shows briefly when the oven starts.
  • Error codeThe code and the full message on the screen.
  • A photoOf the screen or the oven, if you can take one.
  • When it happensDuring preheat, mid-cycle, or as soon as it’s switched on.

Where this comes from. Entries were checked in November 2026 against the manufacturer’s own service manuals: eikon e2s (32Z3923), conneX 12 and 16 (32Z9170), eikon e4s (32Z3870), eikon e3 and e4, eikon e1s, conneX 12e, Mealstream EC401 and 402s. Meanings can still vary with the firmware and the manual revision.

Free phone estimate

E111 on your screen? Call us.

305-447-7384

Monday–Friday, 9 AM–8 PM. For urgent weekend issues, leave a voicemail. Weekend messages are prioritized on Monday.

Prefer that we call you? Leave your number.

Enter your name.
Enter a 10-digit phone number.

We call back during business hours.

Call 305-447-7384 Request